Description
DEIF TMS2-4
Overview
Core Advantages
- Four independent PT100 input channels support simultaneous multi-point temperature tracking
- Onboard sensor fault detection identifies open-circuit and short-circuit failures instantly
- Flexible threshold configuration allows separate setup for pre-alarm and protective shutdown
- Optimized EMC shielding maintains stable operation amid heavy electromagnetic interference
- Wide DC input range adapts to variable onboard power supply of generator systems
- Standard DIN rail form factor enables space-saving installation inside control cabinets
- Parameter adjustment accessible via dedicated configuration communication tools
- Rugged hardware construction suitable for continuous unattended operation

DEIF-TMS2-4
Technical Specifications
| Item | Specification |
|---|---|
| Model | TMS2-4 |
| Manufacturer | DEIF |
| Product Category | Multi-channel Temperature Monitoring Module |
| Supported Sensor | PT100 RTD |
| Input Channels | 4 channels |
| Auxiliary Supply | 18 VDC ~ 32 VDC |
| Mounting Method | DIN rail mounting |
| Communication | DEIF dedicated internal bus |
| Built-in Functions | Temperature measurement, sensor diagnostics, alarm output |
| Operating Temperature | -20 °C ~ +60 °C |
| Storage Temperature | -40 °C ~ +85 °C |
| Relative Humidity | 5% – 95% RH, non-condensing |
| Protection Standard | Surge suppression, reverse polarity protection |
Installation & Commissioning Guidelines
Prior to mounting, visually inspect the module casing, terminal blocks and circuit board for any physical damage. Confirm compatibility with the existing DEIF genset controller architecture before wiring commences.
All installation work must be performed with power disconnected. Anti-static precautions are required to avoid damaging internal electronic components. Secure the module firmly onto the DIN rail to prevent shifting caused by mechanical vibration.
Application Scenarios
Marine Generator Vessels
Monitor engine bearing, cylinder and exhaust temperatures on onboard diesel gensets, complying with marine equipment environmental requirements.
Land-based Diesel Generating Stations
Thermal protection for backup power units, ensuring over-temperature protection during peak-load operation.
Combined Heat & Power Plants
Continuous temperature tracking of internal combustion engines for distributed power generation equipment.
Industrial Off-grid Power Facilities
Support remote monitoring and automatic protection for stationary gensets in mining, construction and remote industrial sites.
Genset Control System Retrofit Projects
Suitable for upgrading temperature monitoring sections of existing DEIF control systems with straightforward integration.