Description
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | Bosch Rexroth Indramat |
| Model | PPC-R22.1N-T-NN-P1-NN-FW |
| Material number | 1070170294 |
| Product family | PPC-R22.1 VisualMotion |
| Hardware platform | PRC-R22.1 |
| Housing | RECO unit |
| Mounting system | RECO 02 rack, slot 00 |
| Supply voltage | 24 VDC nominal |
| Permissible voltage | 19.2–30 VDC |
| Maximum controller current | 1.2 A |
| Maximum fuse rating | 4 A, slow-blow |
| Communication interface | Onboard Ethernet and SERCOS |
| Expansion interface | DPM01 PROFIBUS-DP master |
| PROFIBUS connector | 9-pin D-sub |
| Expansion slot U2 | Cover |
| Expansion slot U3 | DPM01 |
| Expansion slot U4 | Cover |
| Firmware configuration | GPP 10 / PROFIBUS master |
| Protection rating | IP20 |
| Operating temperature | 0°C to +45°C ambient, subject to system configuration |
| Weight | Approximately 1.3 kg |
The exact expansion arrangement and material number are documented in the Bosch Rexroth VisualMotion hardware configuration tables. Electrical values are based on the PPC-R22.1 controller family documentation and should be checked against the unit’s rating label.

PPC-R22.1N-T-NN-P1-NN-FW
Product Introduction
Bosch Rexroth PPC-R22.1N-T-NN-P1-NN-FW Motion Controller
The Bosch Rexroth PPC-R22.1N-T-NN-P1-NN-FW is a programmable multi-axis motion and logic controller in the VisualMotion PPC-R22.1 family. It is designed for coordinated machine control, combining onboard Ethernet communication with a DPM01 PROFIBUS-DP master expansion card. The controller operates within a RECO 02 rack architecture and communicates with compatible Rexroth drive systems through its SERCOS interface.
This configuration is associated with material number 1070170294 and the GPP 10 / PROFIBUS master firmware arrangement. The P1 expansion is important when replacing the unit: a .1 controller without the DPM01 card does not provide the same PROFIBUS master functionality. Firmware, drive configuration, and rack position must also match the existing machine installation.
Application Scenarios & Field Pitfalls
Typical application scenarios
- Multi-axis machine control: Coordinates motion and logic functions across compatible servo axes in industrial machinery.
- PROFIBUS-DP integration: Acts as a master for connected PROFIBUS-DP field devices and compatible automation components.
- Servo drive coordination: Communicates with Rexroth IndraDrive, Diax 04, and EcoDrive 03 drive systems through the supported motion-control architecture.
- Packaging and production machinery: Supports synchronized motion, machine sequencing, and programmable control operations.
Field pitfalls and verification points
- PROFIBUS hardware: Confirm that the replacement includes the DPM01 card in slot U3. A controller with an empty U3 position cannot provide the same PROFIBUS master interface.
- Firmware compatibility: Verify the GPP 10 and PROFIBUS master firmware configuration. Firmware differences can affect drive communication and PLC application behavior.
- Material number: Match material number 1070170294, not just the .1N family designation.
- Ethernet and SERCOS distinction: Ethernet and SERCOS serve different communication functions. Confirm the existing network architecture before changing cabling or configuration.
- Rack installation: The controller is designed for the RECO 02 system and its specified slot arrangement. Check the rack position, orientation, and backplane connections.
- PROFIBUS addressing: Record master configuration, slave addresses, bus termination, baud rate, and diagnostic settings before replacement.
- Power supply: Confirm the 24 VDC supply remains within the documented 19.2–30 VDC range and has sufficient capacity for the controller and connected I/O bus.
- Application backup: Preserve the VisualMotion project, firmware identification, drive parameters, and communication configuration. A hardware replacement without the correct project data may prevent the machine from restarting correctly.
Related Products
- .1N-T-NN-NN-NN-FW — Onboard Ethernet configuration without the P1 PROFIBUS master expansion.
- .1N-T-Q1-P1-NN-FW — Adds DAQ03 Link Ring cross-communication alongside the DPM01 PROFIBUS master.
- .1N-T-G2-P1-NN-FW — Combines a master encoder interface with PROFIBUS-DP master functionality.
- .1N-T-T3-P1-NN-FW — Combines an ETH02 10/100 Ethernet expansion with the PROFIBUS master.
- — PROFIBUS-DP master expansion card installed in slot U3 for this configuration.
- DAQ03 — Link Ring cross-communication card used in alternative .1 configurations.
These configurations share the .1 platform but have different expansion hardware and communication capabilities. They are not automatically interchangeable.
Procurement and replacement note: The most important matching identifiers are .1N-T-NN-P1-NN-FW and material number 1070170294. Request photographs showing the complete typecode label, U3 card, Ethernet connection, and firmware identification. Confirm the GPP 10 application configuration and PROFIBUS master settings before installing the replacement.