Key Technical Specifications
| Parameter | Specification |
|---|---|
| Controller model | F30 03 SILworX |
| HIMA part number | 98 2200496 |
| Digital inputs | 20 |
| Digital outputs | 8 |
| Supply voltage | 24 VDC, -15% to +20% |
| Input signal HIGH | 15–30 VDC |
| Input signal LOW | Maximum 5 VDC |
| Output current | 0.5 A on channels 1–3 and 5–7; channels 4 and 8 support higher loads subject to temperature limits |
| Communication | Four-port 10/100BASE-TX Ethernet switch |
| Safety communication | SafeEthernet |
| Operating temperature | 0 to +60°C |
| Protection rating | IP20 |
| Programming software | SILworX |
| Safety capability | Up to SIL 3, Category 4, PL e; applicable railway standards include CENELEC SIL 4 |
Product Introduction
The HIMA F30 03 SILworX is a compact safety controller in the HIMatrix family, designed for applications requiring safety-related logic processing and integrated field I/O. Its 20 digital inputs and 8 digital outputs support safety functions such as equipment interlocking, emergency-stop circuits, and protective shutdown sequences.
The controller communicates with other compatible safety devices through SafeEthernet and is configured using HIMA’s SILworX engineering environment. Its SILworX-specific hardware and firmware compatibility must be checked before integrating it into an existing safety system.

F30 03 SILWORX 209
Application Scenarios & Field Pitfalls
Typical applications
- Emergency-stop and protective circuits: Processes safety-related input signals and controls designated shutdown outputs.
- Machine and process interlocking: Coordinates permissive conditions and protective actions in industrial equipment.
- Distributed safety systems: Exchanges safety data with compatible controllers and remote I/O over SafeEthernet.
- Plant equipment protection: Supports safety logic for pumps, conveyors, compressors, and other machinery where the engineered safety assessment permits its use.
Field considerations
- Programming environment: The F30 03 SILworX is not automatically interchangeable with earlier ELOP II Factory variants. Confirm the firmware generation and engineering software compatibility.
- Output loading: Do not treat all eight outputs as having identical current capacity. Channels 4 and 8 have different load limits, and temperature affects the permitted current.
- Network configuration: Confirm CPU and COM IP addresses, subnet settings, and System ID (SRS) before attempting online communication.
- Safety validation: A replacement controller requires an approved configuration, hardware compatibility review, and documented safety validation. Matching the model number alone does not establish functional equivalence.
- Part-number verification: Check the nameplate for
F30 03 SILworXand98 2200496. The supplied209suffix needs separate confirmation.
Related Products
The following HIMA models are relevant for comparison within the HIMatrix family. They are not assumed to be direct replacements.
- F30 01 SILworX – Earlier F30 SILworX variant; verify firmware and engineering-tool compatibility.
- F30 011 SILworX – Low-temperature F30 variant; its operating range differs from the standard F30 03.
- F30 034 SILworX – Extended environmental variant intended for more demanding temperature and vibration conditions.
- F31 03 SILworX – Related HIMatrix safety controller; hardware and I/O configuration differ.
- F35 03 SILworX – HIMatrix controller with a different integrated I/O arrangement.
- F60 CPU 03 SILworX – HIMatrix controller option for a different system configuration.
Procurement and Replacement Notes
When sourcing an F30 03 SILworX, request clear photographs of the complete nameplate, including the product designation, part number, hardware revision, firmware revision, and production information. Also confirm whether the unit has been tested and whether its communication and I/O functions have been checked.
For a replacement in an operating safety system, compare the existing controller’s hardware and firmware revisions, SILworX project version, network configuration, and safety application requirements. Do not install a replacement solely because its front-panel designation matches.
Procurement identification: HIMA F30 03 SILworX, part number 98 2200496. Treat “209” as an unverified additional identifier until confirmed from the physical label or original documentation.