Description
Product Introduction
The Kongsberg RMP420S Remote Multipurpose I/O Module is designed for distributed marine automation systems that need a flexible interface between field instrumentation and a host controller. Its 32 software-configurable channels can support multiple signal functions, including analog and digital inputs and outputs, resistance temperature detector (RTD) measurements, and selected pulse, frequency, or encoder signals. This configurable design can reduce the number of different I/O module types required in a system, but the supported signal types and electrical limits must be checked against the approved hardware documentation and project configuration.
The RMP420S is associated with Kongsberg marine control and monitoring systems, where remote I/O modules collect field measurements, report equipment status, and execute configured output functions. Its dual remote I/O bus interfaces support redundant communication arrangements. For replacement procurement, do not rely on the model name alone: verify the full part number, hardware revision, software compatibility, channel allocation, and any applicable safety-system approval. A module that looks identical may still require configuration work or system-level validation before it can return to service.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Model | RMP420S / RPM420S listing variant |
| Manufacturer | Kongsberg Maritime |
| Part number | 319824 |
| Product type | Remote multipurpose I/O module |
| Supply voltage | 24 VDC |
| Typical power consumption | 10 W |
| I/O channels | 32 software-configurable channels |
| Analog input | Voltage and current signals; verify ranges in the applicable manual |
| Analog output | Supported; verify channel configuration and electrical limits |
| Digital input/output | Supported, subject to configuration |
| Temperature input | 2-wire or 3-wire RTD support |
| Pulse functions | Pulse, frequency, or encoder input on up to 2 channels, subject to configuration |
| Remote communication | Dual remote I/O process-bus interfaces |
| Diagnostics | Channel and loop monitoring |
| Protection features | Overvoltage protection and protected I/O loop power are described for the RMP420 family |
| Hazardous-area use | Zone 2 approval is documented for the RMP420 family; verify the exact S-version and installation approval |
| Mounting | Verify rail and cabinet requirements in the hardware module description |
| Operating temperature | Confirm against the applicable RMP420S hardware manual |
Engineering note: The manufacturer’s RMP420 datasheet describes the broader product family. Not every specification should automatically be attributed to the RMP420S. For engineering design or safety-critical replacement, use the hardware module description for the exact part number and revision.

RPM420S
Application Scenarios and Pain Points
- Marine alarm monitoring: Collects discrete and analog signals associated with machinery status, alarms, and operating conditions.
- Engine-room instrumentation: Supports configured measurement channels for compatible sensors, including RTD temperature inputs.
- Integrated control systems: Interfaces field signals with a compatible Kongsberg host controller.
- Remote equipment control: Supports configured output signals within the limits of the approved application and electrical ratings.
- Safety-related installations: May be used in approved configurations, but the precise module version and certification must match the installation requirements.
Common field issues include incorrect channel configuration, mismatched signal types, remote-bus communication faults, and differences between the installed and replacement hardware revisions. These can cause missing measurements or failed output tests even when the module powers on normally.
Related Products
These products are related to the Kongsberg remote I/O and controller ecosystem. They are not confirmed direct replacements for RMP420S.
| Model | General function |
|---|---|
| RMP420 | Remote multipurpose I/O module |
| RMP422 | Related multipurpose I/O module |
| RMP422S | S-version multipurpose I/O module |
| RMP422Si | Multipurpose input module with HART |
| RDIO420S | Remote digital I/O module |
| RDIOR420 | Remote digital I/O module with relay outputs |
| RHUB200-5 | Remote I/O bus hub |
| RCU502i | Remote controller unit |
| RTB420 | Remote termination board |
Engineer’s Guide: Field Pitfalls to Avoid
1. Resolve the RPM/RMP naming difference. Manufacturer documentation uses , while some commercial listings use RPM420S. Match the actual nameplate and part number 319824 rather than relying on a text-only listing.
2. Check every channel against the application. A configurable channel is not automatically suitable for any field signal. Confirm signal type, input range, wiring arrangement, output load, and channel assignment before commissioning.
3. Verify bus redundancy and safety approval. Inspect both remote-bus connections, termination, and controller diagnostics. If the module is installed in a safety-related system, confirm the exact revision and approved configuration before returning equipment to service.
Frequently Asked Questions
Q1: What is the Kongsberg used for?
It is a remote multipurpose I/O module used in compatible marine automation systems to interface field signals with a host controller.
Q2: Is RPM420S the same as ?
RPM420S appears in some supplier listings, but Kongsberg documentation uses . Confirm the physical label and part number before purchasing.
Q3: What is the part number for ?
The associated part number is 319824. Verify the number on the installed module, since similar Kongsberg I/O models use different part numbers.
Q4: How many channels does the module have?
The RMP420 family is specified with 32 software-configurable multipurpose channels. Confirm the exact signal capabilities and configuration rules for the revision in use.
Q5: What power supply does the require?
Published supplier information lists 24 VDC and approximately 10 W typical power consumption. Check the exact module documentation and cabinet power budget before installation.
Q6: Can RMP420 replace ?
Do not assume direct interchangeability. Compare part numbers, hardware revisions, software compatibility, application configuration, and any required certification before approving a substitution.
Q7: What should be checked when buying a refurbished ?