Foxboro FDC280 RH101KF | FDC Baseplate | 2-Position Controller Mount

  • Controller: FDC280
  • Baseplate Part Number: RH101KF
  • Manufacturer: Foxboro / Schneider Electric
  • System: Foxboro DCS / Foxboro Evo / EcoStruxure Foxboro DCS
  • Product Type: Dedicated FDC280 controller baseplate
  • Baseplate Position Count: 2
  • Core Function: Provides the mounting, power, communication, and interconnection platform for FDC280 modules.
  • Supported Configuration: Single FDC280 or two-module fault-tolerant FDC280 arrangement
  • Controller Part Number: FDC280
  • Controller Module Part Number: RH101FQ
  • Mounting: Dedicated baseplate installation
Category: SKU: Foxboro FDC280 RH101KF

Description

Foxboro FDC280 RH101KF Field Device Controller Baseplate

 

Key Technical Specifications

Parameter Specification
Baseplate Model RH101KF
Compatible Controller Foxboro FDC280
Manufacturer Foxboro / Schneider Electric
Product Type FDC280 baseplate
Position Count 2 controller positions
Controller Configuration Single or fault-tolerant pair
FDC280 Module RH101FQ
Primary Function Controller mounting and system interconnection
Power Architecture FDC280 system power connections
Network Connections FDC280 network-adapter connections
Serial Connections serial I/O connections
Time Strobe Direct time-strobe connection
Mounting Dedicated baseplate installation
Compatible Network Adapters RH924WA fiber / RH924UQ copper, subject to revision
System Environment Foxboro DCS / Foxboro Evo

The physical specification lists RH101KF as the baseplate and RH101FQ as the controller module. Schneider also identifies RH924WA as the fiber adapter and RH924UQ as the copper adapter, with minimum revision requirements specified in the documentation.

 

Product Introduction

The Foxboro RH101KF is the dedicated two-position baseplate for the Field Device Controller. It is not an I/O module and does not perform control logic by itself. Its job is to provide the physical and electrical platform into which controller modules are installed, including the connections required for power, communications, serial field-device interfaces, and time synchronization.

The two-position design is particularly important in fault-tolerant installations. Schneider Electric states that a fault-tolerant uses two processor modules with interconnecting fault-tolerant communication integrated into the baseplate. The controller modules must occupy the dedicated positions to maintain the intended architecture and cooling arrangement.

FDC280

Engineering Pain Point

The main replacement risk with RH101KF is treating it as an ordinary passive mounting plate. It is part of the system architecture and establishes the electrical and communication interface between the controller modules and the field-device/network hardware. A physically similar Foxboro 200 Series baseplate should not be substituted simply because it fits the cabinet. Schneider’s documentation specifically excludes RH101KF from the general 200 Series baseplate family and identifies it as the dedicated baseplate.

Typical Applications

  • Foxboro field-mounted controller installations
  • Single controller configurations
  • Fault-tolerant installations using two controller modules
  • Direct integration of PLCs, drives, and other distributed field devices
  • Foxboro DCS installations requiring Ethernet and serial field-device interfaces

Technical Pitfalls to Avoid

  1. Do not confuse with RH101FQ. is the baseplate; RH101FQ is the documented module part number.
  2. Do not substitute a standard 200 Series baseplate. Schneider explicitly identifies as the dedicated baseplate.
  3. Check whether the application is simplex or fault-tolerant. A fault-tolerant installation requires two modules and the appropriate baseplate arrangement.
  4. Verify network-adapter revisions. The documentation specifies RH924WA Rev. E or later for fiber and RH924UQ Rev. D or later for copper applications.
  5. Check cabinet orientation and cooling. Schneider’s installation documentation specifies the baseplate arrangement and mounting orientation requirements associated with controller cooling.
  6. Do not assume the baseplate contains the controller. is the mounting/interconnection assembly; the controller modules are separate components.

 

Related Products

  • — Field Device Controller that installs on the baseplate and performs process control and direct field-device integration.
  • Foxboro RH101FQ — controller module identified by Schneider’s physical specification.
  • Foxboro RH924UQ — Copper network adapter for installations; Schneider specifies Rev. D or later in the cited documentation.
  • Foxboro RH924WA — Fiber network adapter for installations; Schneider specifies Rev. E or later in the cited documentation.
  • Foxboro RH100HZ — 5.0 m Type 5 termination cable used with the serial termination architecture.
  • Foxboro RH100HV — 1.0 m Type 5 termination cable.
  • Foxboro RH100HW — 1.5 m Type 5 termination cable.
  • Foxboro RH100HX — 2.0 m Type 5 termination cable.
  • Foxboro RH100HY — 3.0 m Type 5 termination cable.

 

Procurement Note

For a replacement order, specify as the , not as an controller module. Confirm whether the existing system uses one or a two-module fault-tolerant arrangement, then verify the installed network adapters, serial termination hardware, cable lengths, and controller revision.

The key distinction is:

= controller
RH101FQ = documented module part number
= dedicated 2-position baseplate

That distinction should be preserved on the purchase order and during cabinet-level replacement work.