Honeywell 05704-A-0146 | Four-Zone Fire Card | Industrial Fire Detection

  • Model: 05704-A-0146
  • Manufacturer: Honeywell Analytics
  • Product Series: System 57 / 5704F
  • Product Type: Four-zone fire control card
  • Core Function: Monitors four fire zones and manages fire-control outputs and relay signaling.
  • Lifecycle: Listed as discontinued by a supplier; confirm current stock and revision before procurement.
Category: SKU: Honeywell 05704-A-0146

Description

Technical Specifications

Parameter Specification
Part number 05704-A-0146
Product designation 5704F Fire Card
System Honeywell System 57
Fire zone inputs 4
Switched DC outputs 2 monitored output circuits
Remote input Single three-function remote input
Supply voltage 21–32 VDC
Power consumption Approximately 2 W in one published specification; verify against the applicable hardware revision
Operating temperature -5°C to +55°C
Storage temperature -25°C to +55°C
Operating humidity 20–90% RH, non-condensing
Dimensions 3U high × 25 mm wide
Weight Approximately 175 g
Approval reference EN 50270

Specification caution: Some supplier listings report different power-consumption figures and describe relay capacity differently. The 5704F system documentation identifies separate relay-interface hardware, including the 05704-A-0123 and 05704-A-0133. Do not assume that all relay outputs are physically onboard the 05704-A-0146 card.

 

Product Introduction

Honeywell 05704-A-0146 5704F Fire Control Card

The Honeywell 05704-A-0146 is a four-zone fire-control card designed for the System 57 5704F fire and gas detection platform. It monitors four fire zones, provides two monitored switched DC output circuits, and supports remote control functions. Its narrow 25 mm form factor allows installation in the designated System 57 rack architecture.

05704-A-0146

For maintenance teams, the main procurement consideration is preserving the original fire-zone configuration and output behavior. Replacement work should include verification of the rack position, interface hardware, remote-input wiring, and relay configuration. A card that physically fits the rack is not automatically a functionally equivalent replacement.

 

Application Scenarios & Field Pitfalls

The 05704-A-0146 is intended for fire detection and alarm-control installations using the Honeywell 5704F architecture. It is relevant where an existing System 57 installation requires replacement of a failed fire-control card without changing the established detection and alarm arrangement.

Typical application scenarios

  • Industrial fire-zone monitoring: Supervises four configured fire zones in a System 57 installation.
  • Fire alarm output control: Operates two monitored switched DC output circuits.
  • Remote alarm management: Supports remote accept, reset, and silence functions.
  • Legacy fire-system maintenance: Provides a replacement reference for existing 5704F rack installations.

Field engineering warnings

  1. Check the system family. The 05704-A-0146 is a 5704F fire card. Do not confuse it with 05704-A-0144 or 05704-A-0145, which are four-channel control cards for the standard 5704 system.
  2. Verify relay-interface hardware. Confirm whether the installation uses the 05704-A-0123 Hex Relay Interface Card or 05704-A-0133 Relay Interface Assembly. Check the actual wiring and configured relay functions before commissioning.
  3. Check supply and output circuits. Confirm the installed supply falls within the documented 21–32 VDC range and inspect field wiring, fusing, and monitored output circuits.
  4. Perform functional testing. After installation, test all four fire zones, fault responses, remote functions, and configured alarm outputs. Do not return the fire protection system to service based only on a successful power-up.

 

Related Products

These parts belong to the Honeywell System 57 ecosystem, but they are not interchangeable substitutes for the 05704-A-0146.

Model Product function and relationship
05704-A-0123 5704F Hex Relay Interface Card. Provides relay-interface functionality; verify the installed relay configuration.
05704-A-0133 5704F Relay Interface Assembly. Separate relay-interface hardware for 5704F installations.
05704-A-0148 5704F Fire Status Panel. Provides fire-system status indication rather than the four-zone control function.
05704-A-0144 Standard 5704 four-channel catalytic control card. Different detection application and system configuration.
05704-A-0145 Standard 5704 four-channel 4–20 mA control card. Not a direct fire-card replacement.
05704-A-0121 Standard 5704 quad relay interface card. Different system-family application.
05704-C-0160 5704 interconnection cable. Check connector and rack compatibility before use.

Procurement recommendation: For a replacement order, confirm the complete part number 05704-A-0146, front-panel condition, PCB revision, and compatibility with the installed 5704F relay-interface arrangement. For a safety-related fire detection system, require documented functional testing before the replacement card is accepted for service.