Description
Product Introduction
A failed interface module can interrupt communication between legacy control equipment and connected devices, even when the main controller remains operational. The DATEL ICP232.2-5V, part number 029.361.114, is referenced in industrial spare-parts catalogs, but the available descriptions do not establish a single, authoritative hardware function.
For a replacement purchase, verify the original manufacturer’s label, connector layout, supply voltage, and interface specification before installation. The full ICP232.2-5V 029.361.114 identifier is useful for sourcing, but it should not be treated as proof of protocol compatibility.
Key Technical Specifications
| Parameter | Available information |
|---|---|
| Model | ICP232.2-5V |
| Part number | 029.361.114 |
| Manufacturer attribution | DATEL, according to supplier listings |
| Product category | Industrial interface module; exact function unconfirmed |
| Supply voltage | Some listings specify 5 VDC; verify on the unit |
| Communication interface | Conflicting descriptions; requires confirmation |
| Data rate | Not reliably verified for this exact part |
| Connector / pinout | Not verified |
| Isolation rating | Not verified from primary documentation |
| Operating temperature | Not reliably verified |
| Mounting / form factor | Confirm from physical dimensions and installation documentation |
| Lifecycle status | Current manufacturer support status not independently confirmed |
Supplier descriptions vary substantially: one identifies a VME controller with Ethernet and CAN interfaces, while others associate the model with serial communications or signal conversion. These descriptions should not be combined into a single specification sheet without manufacturer documentation.
Application Scenarios & Pain Points
The main risk when sourcing this part is confusing components with similar model strings but different electrical functions.
- Legacy automation maintenance: Match the installed module’s label and equipment documentation before sourcing a spare.
- Serial communication troubleshooting: If the module is part of a serial link, confirm the electrical standard and connector wiring rather than assuming RS-232 or RS-485.
- Control cabinet repair: Check the supply voltage and polarity before connecting a replacement.
- Obsolete equipment sourcing: Request clear product photos and a documented functional test when manufacturer support or published documentation is limited.
Field tip: photograph the installed module and its connector before removal. Record all markings, jumper positions, cable connections, and the equipment slot. These details often resolve identification problems faster than a catalog title.

ICP232.2-5V 029.361.114
Related Products
The following are verification references or broader product categories, not confirmed compatible replacements.
- DATEL ICP232.2-5V — Same model designation without the separate part-number suffix; confirm that the physical hardware matches.
- DATEL serial interface modules — Compare interface standard, supply voltage, isolation, and connector pinout.
- VME controller modules — Relevant only if the installed part is confirmed to be a VMEbus controller.
- Industrial signal-conditioning modules — Relevant only if the original equipment documentation confirms an analog conversion function.
Do not substitute a product from one category for another based solely on the ICP232 model string.
Engineer’s Guide: Three Replacement Checks
1. Verify the physical identity. Match the complete label, part number, PCB markings, and connector arrangement. If the installed unit is a VME card, a small serial converter or signal-conditioning module is not an equivalent replacement.
2. Confirm the supply and interface. Check the documented input voltage, polarity, signal levels, communication standard, and pinout. Never apply 24 VDC to a unit labeled for 5 VDC operation.
3. Request evidence before purchase. Ask for actual-unit photographs, a test report identifying the tested functions, and written warranty terms. For legacy components, generic statements such as “tested” or “compatible” are not enough to establish suitability.
Frequently Asked Questions
What is DATEL .2-5V 029.361.114?
It is a model listed by industrial spare-parts suppliers under the DATEL name. However, online descriptions disagree about whether it is a serial interface module, a VME controller, or another signal-processing component. The precise function remains unverified.
Does the module use a 5 VDC power supply?
Several listings associate the model with 5 VDC, but confirm the nameplate and original documentation before energizing it. Do not infer the supply rating from the 5V portion of the model number alone.
Does it support RS-232, RS-485, or Ethernet?
I could not establish a definitive interface specification for this exact part from a primary manufacturer source. Check the board markings, connector pinout, and equipment manual before connecting it to a communications network.
Can I use it as a direct replacement for an existing .2-5V?
Only after confirming the part number, hardware revision, supply requirements, connector, and interface function. Similar model numbers do not guarantee identical electrical characteristics.
How can I verify whether a unit is new or refurbished?
Request photos of the actual unit, label and PCB markings, a condition statement, and a test report. For refurbished stock, ask which functions were tested and whether the warranty covers functional failure.
What should I send with a quotation request?
Provide the full model and part number, photos of the installed module, the host equipment model, required condition, and delivery deadline. Ask the supplier to confirm the interface type, supply rating, test scope, warranty, and lead time in writing.
Is the module obsolete?
I could not verify an authoritative manufacturer lifecycle notice for this exact part. If it is being used in a legacy installation, establish current support and available replacement options before planning a long-term maintenance strategy.
Procurement recommendation: Before ordering, obtain a clear photo of the actual .2-5V 029.361.114 label and connector side. Confirming whether this is a serial interface, controller card, or signal-conditioning module is essential to avoid sourcing the wrong hardware.