ABB REC670 1MRK002814-AC | Substation Bay Control and Automation IED

  • Model: REC670
  • Part Number: 1MRK002814-AC
  • Brand: ABB
  • Series: Relion 670 Series
  • Core Function: Provides bay-level control, monitoring, interlocking, measurement, and automation for high-voltage and medium-voltage substations.
  • Product Type: Bay Control Intelligent Electronic Device (IED)
  • Key Specs: Relion 670 Series; Product Version 1.2; configurable binary I/O and voltage/current measurement functions.
  • Communication: Supports substation communication architectures including IEC 61850, with additional interfaces dependent on installed hardware.
  • Auxiliary Supply: The REC670 platform supports 24–60 VDC and 90–250 VDC power-supply variants; verify the installed unit’s power-supply module.
  • Condition: Verify actual stock condition, hardware revision, firmware, and configuration before purchase.
Category: SKU: ABB REC670 1MRK002814-AC

Description

Key Technical Specifications

Parameter Value
Manufacturer ABB
Product Family Relion 670 Series
Model REC670
Product ID 1MRK002814-AC
Product Version 1.2
Product Type Bay Control IED
Primary Application Substation bay control and automation
Typical Applications Feeder, transformer, bus-coupler, capacitor-bank and other switchgear bays
System Frequency 50/60 Hz
Current Inputs 1 A / 5 A, configuration dependent
Voltage Inputs 110 V nominal reference, configuration dependent
Binary Inputs Configurable; voltage-dependent input modules available
Binary Outputs Configurable relay outputs
Auxiliary DC Supply 24–60 VDC or 90–250 VDC variants
Process Bus IEC 61850-9-2 support available in applicable configurations
Station Communication IEC 61850 and other protocol/interface options according to hardware
Engineering Tool ABB PCM600
Front Protection IP40; IP54 with sealing strip
Case Protection IP20 on sides/top/bottom in standard configuration
Mounting Panel/rack installation
Application Architecture Bay-level control, interlocking, monitoring and automation

The REC670 technical documentation lists the device as a pre-configured Bay Control REC670, Product Version 1.2. The same documentation specifies power-supply modules covering 24–60 VDC and 90–250 VDC nominal input ranges.

For analog protection/measurement modules, the 670 platform supports 1 A or 5 A current inputs and 110 V-class voltage inputs. Exact installed channels depend on the hardware configuration.

 

Product Introduction

ABB REC670 1MRK002814-AC

The ABB REC670 1MRK002814-AC is a Relion 670 Series Bay Control IED designed to supervise and control electrical switchgear at the substation-bay level. It can handle breaker and disconnector control, interlocking, status indication, measurement, event handling, and substation automation functions within a configured application.

Its practical value is not simply “control.” The REC670 can consolidate bay logic and operating information into one IED while communicating with the station automation system. That is particularly useful in substations where breaker control, interlocking, synchrocheck, measurements, and remote supervision need to be coordinated.

REC670

Application Scenarios & Field Pitfalls

Engineering Pain Point

A bay-control replacement can look deceptively easy. The wiring may fit, the display may start, and the relay may communicate with the station. Then a breaker refuses to close because an interlock, disconnector indication, synchrocheck condition, or binary-input assignment does not match the original engineering. With , configuration is part of the hardware replacement. Treating it like a generic relay is asking for commissioning problems.

Typical Applications

  • Transmission Substations — Bay control for breakers, disconnectors, earth switches, interlocking, measurements, and station automation.
  • Power Generation — Switchyard and generator-bay control, including breaker supervision and operating-state indication.
  • Industrial Substations — Transformer and feeder bay automation in large process plants and utility distribution systems.
  • High-Voltage Switchgear — Bus-coupler, bus-section, feeder, transformer, and capacitor-bank bay control applications.

Technical Pitfalls to Avoid

  1. Do not confuse with a dedicated protection relay.
    ‘s primary role is bay control and automation. It can contain protection-related functions depending on configuration, but its engineering purpose is broader than a simple overcurrent relay.
  2. Verify the exact hardware configuration.
    The platform uses modular analog and binary I/O arrangements. The complete product code and installed hardware determine what signals are physically available. The 1MRK002814-AC designation should be checked against the nameplate and project documentation.
  3. Check auxiliary power before installation.
    power-supply modules are available for different DC voltage ranges. The technical documentation lists 24–60 VDC and 90–250 VDC variants. Do not connect a plant’s 24 VDC supply to a unit configured for a high-voltage DC power module.
  4. Back up the PCM600 project.
    Save the complete IED configuration, application logic, communication settings, I/O mapping, and parameter set before removing the original device. Recreating bay logic manually during an outage is avoidable.
  5. Verify interlocking logic point by point.
    Breaker-close permissives, disconnector positions, earth-switch status, local/remote selection, and mechanical interlocks must correspond to the actual switchgear. A single inverted binary input can block an otherwise healthy bay.
  6. Check synchrocheck configuration where applicable.
    If the controls breaker closing across energized sections, verify voltage inputs, phase-angle settings, frequency difference, voltage difference, and dead-line/dead-bus logic. Do not assume these settings transfer automatically between projects.
  7. Do not assume identical communication hardware.
    IEC 61850 capabilities exist within the platform, but the physical communication interfaces and configured protocols depend on the installed hardware. Confirm the station-bus architecture before ordering a replacement.
  8. Test the complete operating sequence.
    A successful communication test is not enough. Test local control, remote control, interlocking, breaker indication, disconnector indication, alarms, trip/close outputs, and station-control-system feedback.
  9. Respect the CT/VT circuits.
    Where analog measurement inputs are used, verify CT ratios, VT ratios, polarity, phase sequence, and wiring. An incorrect phase assignment can produce believable but wrong measurements.

 

Related Products

  • ABB 1MRK002814-AB — Closely related ordering variant. It belongs to the same bay-control platform, but the complete hardware and configuration must be compared before substitution. The -AB and -AC suffixes should not be treated as interchangeable part numbers.
  • ABB 1MRK002814-AC Version 1.2 — The product-version configuration associated with the requested unit. This is the relevant reference when maintaining an existing Version 1.2 installation.
  • ABB REF670 — Feeder protection IED in the Relion 670 family. It is primarily intended for feeder protection, while focuses on bay control and automation. The two can be complementary within the same substation.
  • ABB RET670 — Transformer protection IED. It is used for transformer differential, earth-fault, and related transformer protection functions. can provide bay-control functions around a transformer bay, while RET670 handles transformer protection.
  • ABB REB670 — Busbar protection IED. It provides dedicated busbar differential protection and can operate alongside in substations where bay control and busbar protection are separated.
  • ABB REL670 — Line protection IED for transmission-line applications. It performs dedicated line protection functions rather than the bay-control role of .
  • ABB REG670 — Generator protection IED for generator and generator-transformer applications. It can complement in generating-station switchyards.
  • ABB PCM600 — Engineering and configuration environment used for compatible ABB protection and control IEDs. For replacement work, the PCM600 project is often as important as the physical relay because it contains the application logic and configuration.
  • ABB Relion 670 Series — Common IED platform containing , RET670, REB670, REF670, REL670, REG670 and other application-specific devices. Shared platform architecture does not make the individual IEDs direct substitutes.