Description
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | ABB |
| Model designation | CMA198 |
| Variant referenced in product listings | CMA198/A |
| Product type | Analog output module |
| Application | Industrial control signal output |
| System association | ABB Advant / S100 I/O, subject to configuration verification |
| Output signal types | Voltage and current are reported for CMA198/A; exact ranges require confirmation |
| Number of channels | Not independently verified |
| Resolution and accuracy | Not independently verified |
| Supply voltage | Confirm against the exact hardware documentation |
| Terminal unit | Confirm the installed I/O terminal unit and module compatibility |
| Operating temperature | Not independently verified for the exact variant |
| Order number | Not provided; verify the complete ABB part number on the label |
Procurement caution: Do not use unverified channel counts, resolution figures, or supply-voltage values to approve a replacement. Obtain the manufacturer’s documentation for the exact CMA198 variant and compare it with the installed module.
Application Scenarios & Pain Points
An analog output fault can interrupt a control loop even when the controller continues running normally. Before replacing the card, establish whether the fault follows the module or remains with the field wiring and actuator.
- Process control: Analog command signals for compatible modulating devices, subject to the module’s documented output range.
- Valve and actuator control: Potential use in loops that require voltage or current references. Confirm load requirements and signal type before connecting the field device.
- Legacy ABB system maintenance: Replacement planning for an existing installation where the CMA198 designation appears in the equipment bill of materials.
- Control cabinet refurbishment: Evaluation of an existing output module when maintaining the installed architecture is preferable to a wider system migration.
Field note: If an actuator remains stationary after a card replacement, check the output configuration, common reference, field wiring, and actuator input requirements before concluding that the replacement module is defective. A matching model label alone does not verify correct loop operation.

CMA198
Related Products
These ABB modules may be relevant when maintaining an Advant control system. Their functions differ, and none should be treated as a direct replacement for CMA198 without checking the hardware documentation and system configuration.
- ABB CMA132 — 3DDE300412: Analog input module for direct temperature-sensor measurements in documented configurations. Intended for acquiring temperature signals rather than generating analog control outputs.
- ABB CMA121: Analog input module for compatible transmitter signals. Consider it for measurement loops; it does not replace an analog output module’s function.
- ABB /A: The suffix-designated variant associated with analog output applications. Confirm the complete order number before treating it as equivalent to a bare designation.
- ABB MP800M: MasterPiece controller family component used in legacy Advant control architectures. It performs controller-level functions rather than analog output conditioning.
- ABB MP200: MasterPiece controller family component for compatible Advant systems. Its role differs from a dedicated I/O module.
- ABB TU810: Terminal unit associated with S100 I/O configurations in some installation references. Verify the precise module and terminal-unit compatibility before reuse.
- ABB TU812: Another terminal-unit option referenced in S100 I/O applications. Check the terminal layout and hardware documentation; do not assume interchangeability.
- ABB TU813: Terminal unit used in certain S100 I/O arrangements. Confirm the specific mounting and wiring requirements for the installed system.
These related models serve different roles: analog input modules acquire signals, controllers execute control logic, terminal units provide physical connections, and analog output modules generate control signals.
The Engineer’s Guide: Field Pitfalls to Avoid
Warning 1 — Ordering by the shortened model designation
alone may not identify the complete hardware variant.
How to avoid it:
- Photograph the module’s full nameplate.
- Record the complete model, suffix, and order number.
- Compare the replacement against the installed hardware documentation before purchase.
Warning 2 — Mismatched output signal and field device
A voltage-input actuator will not necessarily operate correctly from a current-output configuration. The permissible output range and load also matter.
How to avoid it:
- Identify whether the control loop requires voltage or current.
- Check the field device’s input specification and wiring diagram.
- Verify the configured output range and scaling during commissioning.
Warning 3 — Terminal-unit or controller incompatibility
A module’s physical fit does not establish electrical or system compatibility. Incorrect terminal assignments or an unsupported configuration can cause commissioning failures.
How to avoid it:
- Record the existing terminal-unit model and controller type.
- Check the I/O configuration and relevant engineering documentation.
- Use ESD precautions when handling the replacement, and follow approved shutdown and isolation procedures.
Frequently Asked Questions (FAQ)
1. What is the ABB used for?
Available product references associate /A with analog output applications in industrial control systems. The module’s precise function and supported signal types should be confirmed against the full model designation and manufacturer documentation.
2. Is ABB the same as /A?
Not necessarily. /A is a specific designation found in product references, while is an abbreviated model name. Check the original nameplate and order number before accepting a proposed substitute.
3. Can I use to replace a failed analog output card?
Only if the installed system requires the same hardware and electrical functionality. Confirm the controller family, terminal unit, output signal type, channel requirements, and configuration before installation.
4. How do I verify the condition of a replacement ?
Ask for photographs of the actual unit, including its label and connectors. For refurbished stock, request a test report specifying the checks performed and whether the analog outputs were tested under load. Visual inspection alone cannot establish functional performance.
5. Is a new-surplus covered by the manufacturer’s warranty?
Not automatically. Warranty coverage depends on the product’s provenance, the supplier’s terms, and any applicable manufacturer policies. Obtain written confirmation of the warranty period, exclusions, and return procedure before purchasing.
6. How quickly can I get a replacement?
Availability and lead time depend on the exact variant, stock condition, and inspection requirements. Ask the supplier to confirm the complete part number, physical stock status, test status, and expected dispatch date in writing.
7. What information is needed to identify the correct replacement?
The most useful information is:
- A clear photograph of the full nameplate.
- The complete ABB order number.
- The controller and I/O system model.
- The installed terminal-unit designation.
- The required analog output type and range.